Serial Port Data Logger Company
Alarm-Log%E2%80%941.jpg' alt='Serial Port Data Logger Company' title='Serial Port Data Logger Company' />A Hydra Series III Data Acquisition SystemDigital Multimeter DMMAccurate industrial thermocouple measurements. The 2. 63. 8A incorporates the Fluke patented Universal Input Connector to bring more accuracy to thermocouple measurements than most other instruments in its class. The Universal Input Connector supports 1. Temperature focused menu selections make the 2. Get presentation quality graphics with Onsets HOBOWare Pro data logger software. Quickly readout plot data and export to spreadsheets. Unzip .Z Files In Unix. Priceperformance breakthrough in a standalone data acquisition system. I have a situation in which i want to write all logs created by me to write into a text file. Logger API for generating the logs. I. Add WeatherLink to your Vantage Vue or Vantage Pro2. The data logger fits neatly into the weather station console or Weather Envoy, storing weather data even when it. Data Loggers Multi Channel Programmable Data. Single and Dual Channel Data Loggers for Pressure, Temperature, RH, mA V. LEO Record Pressure Data Logger. FlexPod. This section provides an overview on the FlexPod design. System Overview. FlexPod is a best practice data center architecture that is built with three. Service Names and Transport Protocol Port Numbers 20171114 TCPUDP Joe Touch Eliot Lear, Allison Mankin, Markku Kojo, Kumiko Ono, Martin Stiemerling, Lars Eggert. Antena 1 Program Maine. A especially suitable for temperature validation applications. If you need to zero a large number of thermocouples to a known reference temperature before starting a temperature profiling or validation test, the 2. Keygen Iveco Easy Software. A will normalize all readings to your reference channel at the push of a button and store the offsets for reference in a supporting data file. If you are conducting chamber tests, heat treating tests under AMS guidelines, or validating temperature devices under 2. CFR regulations, Hydra Series III makes it that much easier to comply. Universal Input Connector. The Universal Input Connector plugs into any open slot in the 2. A that contains a relay card. The Universal Input Connector has 2. Each input connector contains a CJC cold junction compensation device, which is calibrated at the factory. The calibration date and input connector serial number are programed into the input connector and are read by the 2. A when installed. This information is saved in the test setup data file, which is available for review with any associated scan data from a test setup. This feature is a valuable form of traceability if you are working in a regulated industry. Wiring a test or system setup for 2. With the inexpensive plug in Universal Input Connector, you can wire your system once, quickly disconnect the connector from your Hydra, then reconnect the Hydra to another input connector for use in a different area. Other data loggers require you to wire your inputs directly to an expensive plug in active component signal conditioning module. If you need your instrument for a test at another location, you must remove your wiring or use another expensive plug in signal conditioning module. With Hydra Series III, all your signal conditioning is inside the mainframe, not in your input connector. Using multiple low cost Universal Input Connectors gives you the flexibility to leave your input connector at the test site, completely wired, and ready to use. When you need data from that site, simply plug in and load your saved setup file. Its that simple Expandable channel capacity. Each 2. 63. 8A has three slots in the rear panel. Each slot can hold a user accessible relay card and a 2. Universal Input Connector. Three configurations are available, from 2. Select a base model with 2. The low cost per channel makes the 2. A a good value for any budget. Graphical color display with easy to use menus. Never get lost again in a complex menu tree while configuring channels or setting up a test. The large, full color, thin film diode TFD display enables the Hydra Series III to display comprehensive easy to understand data and easy menu navigation. Back lighted function keys quickly confirm the active menu selection. The Record key illuminates to indicate when the 2. A is recording data in scan, monitor or DMM mode. You always have visible confirmation when your data are being recorded. Copy and paste channel functions make repetitive channel setups a simple task. Top of screen menu bar headings always let you know where you are in the setup process. View your data with the push of a button. Page through all channel data and alarms in a quick view mode or scroll through channels and channel statistics individually. Statistics include rate of change, min, max, standard deviation, average, sample size and peak to peak information. Language support. All displayed text in the menus and data display area are translated to eight languages. You can change the language under the instrument setup area with the push of a button. French, Spanish, Japanese, German, Korean, English, Portuguese, Chinese and Russian are all supported languages in the 2. A. Real time data charting with historical review. Chart the real time data of up to four channels at once. Simply select your channels and view real time charting of your measurements. The chart will auto scale for best fit of the displayed values. Zoom in or out to view areas of interest with the push of a button. A history mode enables you to scroll through previously collected data within the scan fileall without a PC and expensive charting programs. Screen capture function. With one key push on the front panel, you can capture the screen contents of the 2. A directly to the USB drive in. Capture trend chart results or data displays while in any operating mode for reports or just closer review is easy to do. Two alarms per channel. Each channel can be set for two alarm points High High, High Low or Low Low, in any combination. The 2. 63. 8A compares the set points during each scan. An out of range value is reported on the main display and in data files. You can also assign any alarm point to any of six TTL alarm outputs. Math channels. Each channel measurement can be set to scale and record your measurement using mxb gain and offset calculations that are available during your channel setup menu. In addition, each 2. A mainframe has 2. Each channel result can be used as a variable in another math channel calculation. DMM mode adds functionality and value. The Hydra Series III is based on a 6. Hydra to collect multi channel data, you can use it as a digital multimeter. Front panel DMM style input jacks and dedicated DMM menu selections enable you to measure dc voltage, dc resistance, ac voltage, ac resistance, Ohms, frequency, and temperature thermocouples, RTDs and thermistors. Record DMM measurements to a separate DMM data file for later view. The 2. 63. 8A also displays measurement statistics and graphs measurements right on the main display. USB and internal memory. The Hydra Series III features 2. MB on board memory for storing over 5. In addition to this large on board memory, a built in USB port is available to collect and store large files directly to the USB drive. An on board file management menu makes moving data files or configuration files from internal or USB memory to your PC easy. Memory management. The main panel memory key opens a simple menu for managing data files and setup files. If you want to load a previously saved setup file for a test, simply select your file from either internal memory or from a USB drive and you are ready to start scanning. You can easily move stored internal data to a USB for PC analysis or move setup files to another 2. A. With Hydra Series III you have easy access to data without the need for a direct PC connection. To help safeguard your test data in the case of a power outage, the 2. A has a menu selection to resume scanning in the same configuration immediately when power is restored. It is just another way the 2. A works with and protects your data. Flexible triggers and resolution. To begin a scan, you have several options that can be set in your test setup menu External trigger to the rear panel Remote SCPI command Alarm trigger Time interval trigger Manual trigger initiated from the front panel. Measurement resolution is at your control with the 2. A. You can choose between standard settings of Fast, Medium or Slow 4.